Fluke Networks SimpliFiber Pro Optical Power Meter and Fiber Test Kits Price in Nairobi Kenya
- Single-port, simultaneous dual-wavelength feature completes testing in half the time and saves measurements from both wavelengths into one record
- Additional wavelengths of 1490 and 1625 nm
- CheckActive™ feature emits an audible tone and displays an icon when a live fiber is detected, eliminating the need to set up a measurement
- FindFiber™ Remote ID enables one individual to quickly identify cable connections or routings (especially useful at patch panels), eliminating the need for multiple technicians on opposite ends of a fiber link to match color combinations
- Min/Max capability automates precision tracking of intermittent power fluctuations
- Large internal memory save 1000 results which enables continuous testing and recording
Product Description
Environmental Specifications | |
Operating Temperature | -10º C to 50º C |
Storage Temperature | -20º C to 50º C |
Operating Humidity |
|
EMI, RFI, EMC | Standards compliant1 |
1 Conforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)
Optical Power Meter | |
Detector Type | InGaAs |
Calibrated Wavelengths | 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm |
Measurement Range |
|
Power Measurement Linearity |
|
Power Measurement Uncertainty3 | ±0.25 dB |
Display Resolution, dB or dBm | 0.01 dB |
Auto Dual-Wavelength Switching | Yes |
Power Display Units | dBm, mW, μW |
Auto-Wavelength Detection | Yes |
Data Storage | 1000 records, multiple wavelengths per record |
External Interface | USB, 2.0 full speed |
Optical Connector | Removable adapter, SC adapter as default, optional adapters include LC, ST |
Display update rate | 1 reading per second |
Reference | Individually set for each wavelength |
FindFiber ID detection | Yes |
Power Requirement | 2 AA Alkaline batteries |
Battery Life4 | > 50 Hours (typical) |
Automatic Power Off | 10, 20, 30 or 60 minutes (can be disabled by user) |
Low Battery Warning | Yes, low battery icon blinks |
Size (L x W x H) | 6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm) |
Weight | 11.5 oz (325 grams) |
1 For 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power < -45 dBm
2 ±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power > 0 dBm and < -55 dBm
3 23°C ±2°C, power level -20dBm, continuous wave, 62.5/125µm at multi mode wavelengths, 9/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,
4 For measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
Multimode Optical Source | |
Emitter Type | LED |
Central Wavelength | 850 nm, 1300 nm |
Wavelength Accuracy |
|
Spectral Width (FWHM) |
|
Minimum Output Power | 850/1300 nm: ³ -20 dBm |
Power Output Stability1 | ±0.1 dB over 8 hours |
Auto Dual-Wavelength Switching | Yes. Can be enabled/disabled by user. |
Optical Output Connector | Fixed SC |
FindFiber Code Generation | Yes. Fixed at ID 1. |
Modes | CW, 2 kHz modulated, Auto-wavelength |
Power Requirement | 2 AA Alkaline batteries. |
Battery Life2 | 40 hrs (typical) |
Automatic Power Off | 30 minutes (can be disabled by user) |
Low Battery Warning | Yes, LED blinks |
Size (L x W x H) | 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm) |
Weight | 1.8 oz (278 g) |
1 23° C ± 2° C, after 5 minutes warm-up time
2 In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
Singlemode Optical Source | |
Emitter Type | 1310 nm/1550 nm: dual FP laser 1490 nm/1625 nm: dual DFB laser |
Central wavelength |
|
Wavelength Accuracy |
|
Spectral width (RMS) |
|
Minimum output power | 1310/1550 nm ≥ -7dBm (typical) 1490 nm/1625 nm: ≥ -3 dBm (typical) |
Power Output Stability1 | ±0.25 dB over 8 hours |
Auto Dual-Wavelength Switching | Yes. Can be enabled or disabled by user. |
Optical Connector | Fixed SC |
Launch Condition | 9/125 μm fiber |
FindFiber Code Generation | 1310/1550 source is fixed at ID 2 1490 nm/1625 nm is fixed at ID 3. |
Modes | CW, 2 kHz modulated, Auto-wavelength |
Power Requirement | 2 AA Alkaline batteries |
Battery Life2 | 30 hrs (typical) |
Automatic Power Off | 30 minutes (can be enabled or disabled by user) |
Low Battery Warning | LED blinks. |
Size (L x W x H) | 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm) |
Weight | 9.8 oz (278 grams) |
1 23° C ± 2° C, after 5 minutes warm-up time
2 In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
FindFiber Source Specifications | |
Emitter Type | Laser |
Source Connector | Fixed SC |
FindFiber Code Generation | 1 through 8. Default is 3. |
Power On/Low-battery Indicator | LED |
Power Requirement | 2 AA Alkaline batteries |
Battery Life | > 80 Hours (typical) |
Automatic Power Off | 30 minutes |
Low Battery Warning | LED blinks |
Size (L x W x H) | 7.1 in x 1.3 in x 1.0 in (17.9 cm x 3.2 cm x 2.5 cm) |
Weight | 4.4 oz (125 g) |
Safety | Meets Class 1 CDRH |