Fluke Networks DSX-8000 CableAnalyzer Price in Nairobi Kenya
The Fluke Networks DSX-8000 copper-testing CableAnalyzers are part of the Versiv family of cable certification products. It consists of the Versiv mainframe, remote units, and two copper certification modules.
The DSX-8000 certifies twisted pair Cat 5e, 6, 6A, 8 and Class I/II cabling with limits up to 2000 MHz.
Product Description
Specification
Cable Types | |
Shielded and unshielded pair LAN cabling | TIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω |
Standard Link Interface Adapters | |
Permanent link adapters | Plug type: shielded RJ45 Optional Plug type: Tera |
Channel Adapters | Jack type: shielded RJ45 Optional Jack type: Tera, GG45 |
Test Standards | |
TIA | Category 3, 4, 5, 5e, 6, 6A, 8 per TIA 568-C.2 |
ISO/IEC | Class C and D, E, EA, F, FA and I/II certification per ISO/IEC |
Maximum frequency | DSX-8000: 2000 MHz; DSX-5000: 1000 MHz |
General Specifications | |
Speed of Autotest | DSX-8000: Full 2-way Autotest of Category 5e or 6/Class D or E: 7 seconds. Full 2-way Autotest of Category 6A/Class EA: 8 seconds. Full 2-way Autotest of Category 8: 16 seconds |
DSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA: 10 seconds | |
Supported test parameters (The selected test standard determines the test parameters and the frequency range of the tests) | Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F) |
Input protection | Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
Display | 5.7 in LCD display with a projected capacitance touchscreen |
Case | High impact plastic with shock absorbing overmold |
Dimensions | Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm) |
Weight | Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg) |
Main unit and remote: | Lithium ion battery pack, 7.2 V |
Typical battery life: | 8 hours |
Charge time* | Tester off: 4 hours to charge from 10 % capacity to 90 % capacity. |
Languages supported | English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian |
Calibration | Service center calibration period is 1 year |
Integrated Wi-Fi | Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz) |
Environmental Specifications | |
Operating Temperature | 32°F to 113°F (0°C to 45°C) |
Storage Temperature | -14°F to +140°F (-10°C to +60°C) |
Operating relative humidity | 0 % to 90 %, 32°F to 95 °F (0°C to 35°C) 0 % to 70 %, 95°F to 113 °F (35°C to 45°C) |
Vibration | Random, 2 g, 5 Hz-500 Hz |
Shock | 1 m drop test with and without module and adapter |
Safety | CSA 22.2 No. 61010, IEC 61010-1 3rd Edition |
Operating altitude | 13,123 ft (4,000 m) 10,500 ft (3,200 m) with ac adapter |
EMC | EN 61326-1 |
Performance Specifications ** | ||
DSX-8000 | Category 8 test modes (or lower link categories) | ANSI/TIA-1152 Level 2G |
Class I/II test modes | Proposed standard IEC 61935-1 Ed. 5 Level VI | |
DSX-5000 | Category 6A/Class EA test modes (or lower link categories) | Exceed Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1. |
Class FA test modes | Exceed Level V requirements as in the draft 4th edition of IEC 61935-1. |
Length of Twisted Pair Cabling1 | ||
Without Remote | With Remote | |
Range | 800 m (2600 ft) | 150 m (490 ft) |
Resolution | 0.1 m or 1 ft | 0.1 m or 1 ft |
Accuracy | ± (0.3 m + 2 %); 0 m to 150 m ± (0.3 m + 4 %); 150 m to 800 m |
± (0.3 m + 2 %) |
Propagation Delay | ||
Without Remote | With Remote | |
Range | 4000 ns | 750 ns |
Resolution | 1 ns | 1 ns |
Accuracy | ± (2 ns + 2 %); 0 ns to 750 ns ± (2 ns + 4 %); 750 ns to 4000 ns |
± (2 ns + 2 %) |
Delay Skew | |
Range | 0 ns to 100 ns |
Resolution | 1 ns |
Accuracy | ± 10 ns |
DC Loop Resistance Test | |
Range | 0 Ω to 540 Ω |
Resolution | 0.1 Ω |
Accuracy | ± (1 Ω + 1 %) |
Overload recovery time | Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. |
DSX CableAnalyzer™ Series Copper Cable Certifiers
Accelerates every step of the copper certification process
- Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
- Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards
- ProjX™ system manages job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly
- Taptive™ user interface simplifies set-up, and eliminates errors
- Analyze test results and create professional test reports using LinkWare™ management software
- Graphically displays the source of failures including crosstalk, return loss and shield faults for faster troubleshooting
- Intertek Verified to TIA Level 2G – the most stringent accuracy requirement
- Copper cable certifiers endorsed by cabling vendors worldwide
- Built in Alien Crosstalk testing capability
- Compatible with Linkware™ Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare™ PC Cable Test Management Software.
The DSX CableAnalyzer Series copper cable certifiers enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down – setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand.
As part of the Versiv cabling certification product family, the DSX CableAnalyzer Series copper cable certifiers provides accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements. The difference between being profitable or not is just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy, making jobs easier to manage, and getting to system acceptance faster. It’s not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.
Comparing the DSX-8000 and DSX-5000
The DSX CableAnalyzer Series family copper cable certifier is based on two modules: the DSX-5000 and DSX-8000. The DSX-5000 certifies twisted pair Cat 5e, 6, 6A and Class FA cabling with limits up to 1000 MHz. The DSX-8000 certifies twisted pair Cat 5e, 6, 6A, 8 and Class I/II cabling with limits up to 2000 MHz.
Copper Certification | ||
DSX-8000 CableAnalyzer™ | DSX-5000 CableAnalyzer™ | |
Category 6A / Class EA test time | 8 seconds | 10 seconds |
Category 8 / Class I/II test time | 15 seconds | |
HDTDX/HDTDR diagnostic test times | ≈ 3 seconds | ≈ 3 seconds |
Internal memory | ≈ 5,000 Cat 8 with plots ≈ 12,000 Cat 6A with plots |
≈ 12,000 Cat 6A with plots |
Level V Accuracy (1 GHz) | ✓ | ✓ |
Level VI/2G Accuracy (2 GHz) | ✓ | |
Resistance Unbalance measurement | ✓ | ✓ |
Shield integrity check | ✓ | ✓ |
TCL measurement | ✓ | ✓ |
ELTCTL measurement | ✓ | ✓ |
CDNEXT measurement | ✓ | ✓ |
CMRL measurement | ✓ | ✓ |
Built in Alien XTalk module | ✓ | ✓ |
Channel Adapter | 2 GHz Range | 1 GHz Range |
Permanent Link Adapter | 2 GHz Range | 1 GHz Range |
Optional Accessories | ||
Patch cord adapters | Category 5e, 6 and 6A patch cord | Category 5e, 6 and 6A patch cord |
Coax Adapter | ✓ | ✓ |
M12 Adapter | ✓ | ✓ |
TERA Adapter | ✓ | ✓ |
GG45 Adapter | ✓ | ✓ |
Reviews
There are no reviews yet.